total power international, inc. toll free: 877-646-0900(us) ph# (978) 453-7272 www.total-power.com total power international, inc. on-board universal input ac-dc encapsulated modular power supplies 5 watts single & dual output tpam05s & tpam05d series features: on-board ac/dc modular power supplies universal ac input range compact in size meet universal safety standards emi meet cispr pub.22 / fcc class b ce marking compliance specification input specification input voltage: 90-264vac typical. input frequency: 47-63 hz. (50/60hz.nom.). input current: 0.15a @115vac./0.07a @230vac. inrush current: 32.5a peak @ 230vac. input fuse: use external fuse. 1.0a/250vac for the primary fuse is suggested. dielectric withstand: meet iec950. 3,000vac-output/input. 1,500vac-input/gnd. 500vac-output/gnd. emi: meet cispr pub.22 / fcc class b. hold-up time: 20 ms @115vac, 80ms @230vac. earth leakage: less than 3.5ma @230vac. output specification output voltage: see ratings chart. output current: see ratings chart output wattage: 5watts typical. output indicator: led. line regulation : various with output voltages. tpam05s 0.1 % typical. tpam05d 0.5% typical. load regul ation: various wit h output voltage. tpam05s 1.0% typical. tpam05d 2.0% typical. noise & ripple: 1.0% typical peak to peak. ovp: built-in on main output. adjustability: from -10% of main output till ovp. overload protection (olp): fully protected against output overload and short circuit. olp set at about 125-150% rating output wattage. consult the factory for olp setting. general specification efficiency: 64%-78% typical. (various with output voltage). switching frequency: 75k hz. circuit topology: fixed frequency flyback circuit. transient response: typical peak deviation 250mv, recovery time < 3ms for a 25% load change. case: impact resistant thermo-plastic enclosure. weight: 107.0g (3.77 oz). power density: 1.61 watts. / cubic inch. safety standard: en60950/ ul1950 class i. mtbf: 110,000 hours. mil std 217, 25c. operating temperature: -10 to +70c range. -10c to +50c full load without derating. from +50c, derating linearly to half load @+70c. (refer to derating chart.) storage temperature: -20c to +85c. temperature coefficient: 0.03% /c. humidity: up to 95%rh, non-condensing. cooling: convection cooling for +50c @ full load. at least 100lfm moving air is recommended for full load > +50c in a confined area. commercial grade only. note: (1) all measurements are at nominal input , full load, and +25c unless otherwise specified. (2) load regulation measured from full-load (f-l) to half-loa d (h-l) at nominal input and others loaded at half load. due to requests in market and advances in technology , specifications subject to change without notice.
total power international, inc. toll free: 877-646-0900(us) ph# (978) 453-7272 www.total-power.com output voltage/ current ratings chart mechanical dimensions: mm [inches] weight: 107.0g (3.77 oz.) derating chart single output vo1 @ U U
|